PVC

HIGHLIGHT OF THE PRODUCT
  • Smooth internal surface – Pipes have smooth inner surface for far better as compared to AC, CI and GI pipes.

  • Hygienic and odour free – These pipes are most ideal for carrying potable water as it does not contaminate the water.

  • No corrosion – Pipes are highly resistant to any chemical reactions, resulting in a corrosion free pipe.

  • Chemical resistance – Pipes resistant to acids, oxidizing agents, alkalis, oils and domestic effluents.

  • Maintenance free – Being corrosion resistant, PVC pressure pipes does not need for painting or coating.

  • Economical – PVC pipes are light in weight and hence offer total economy in handling, transportation and installation.

  • Manufactured as per IS:4985:2000

CERTIFIED BY

PRODUCT AVAILABILITY AND STANDARDS

VARIENTS SIZES AVAILABLE PIPE FITTINGS
Pressure class 4 kg/cm² 20mm, 25mm, 32mm, 40mm, 50mm, 63mm, 75mm, 90mm, 110mm, 140mm, 160mm, 180mm, 200mm, 250mm IS:4985:2000 IS:4985:2000
Pressure class 6 kg/cm 20mm, 25mm, 32mm, 40mm, 50mm, 63mm, 75mm, 90mm, 110mm, 140mm, 160mm, 180mm, 200mm, 250mm IS:4985:2000 IS:4985:2000
Pressure class 10 kg/cm² 20mm, 25mm, 32mm, 40mm, 50mm, 63mm, 75mm, 90mm, 110mm, 140mm, 160mm, 180mm, 200mm, 250mm IS:4985:2000 IS:4985:2000

INSTALLATION PROCEDURE FOR CPVC FOR SOLAR APPLICATION

a. Installation for solvent cemented jointing

Cutting

De-burring

Cleaning/dry

Apply Lubricant  

Assembling

Solvent cemented jointing –

a. Set time – After application of solvent cement, it takes some time for the joint to set,  subject to atmospheric conditions and pipe diameter

Average initial set schedule for PVC solvent cement

Temperature Range Pipe size ½” – 1¼” (20mm – 40mm)
16⁰ – 38⁰C 2 minutes
5⁰ – 16⁰C 5 minutes
– 18⁰ – -5⁰C 10 minutes

b. Cure time – Curing time is longer time than the set time. Curing means the joint has completely matured.

Average joint cure schedule for PVC solvent cement

Relative Humidity 60% or less Pipe size ½” – 1¼” (20mm – 40mm)
Temperature ranges during assembly & cure periods Bar
up to 11 11 to 26
16⁰ – 38⁰C 15 minutes 6 hours
5⁰ – 16⁰C 20 minutes 12 hours
– 18⁰ – -5⁰C 30 minutes 48 hours

c. The pressure test can only be performed after the joint is completely cured.

d. Compressed air cannot be used for leakage test.

e. In case of using paint on PVC piping system, only Latex based paints which are water based paints wherein the paint concentrate is diluted with water to make it workable and brush able. NO OIL / Solvent based paints are to be used as these paints can drastically reduce the life of the systems.

 

ABOUT TRUFLO

TRUFLO, part of the Somany Impresa Group, offers wide range of world class PVC pipes, fittings and allied products. TRUFLO reaffirms the commitment to quality of Hindware, the flagship brand of Somany Impresa Group, that has been built over six decades. It further strengthens Hindware’s pursuit to provide complete bathroom solutions by complementing its exquisite range of sanitaryware. TRUFLO is one of the fastest growing plumbing brand and aspires to continue offering the best in class range of products and create value for all its stakeholders.

Mailing Address
  • 501 & 504, Block – A, “The Platina”, Survey No.136, Gachibowli Miyapur Road, Gachibowli, Hyderabad, Telangana – 500 032.
Chat with us